INPUT SPECIFICATIONS

Input voltage: 90 to 264 VAC
Input frequency:47 to 63 Hz

PROTECTIONS
Over voltage protection: +3.3V: 3.5V - 4.8V; +5V: 5.5V - 6.82V; +12V: 13.4V - 15.6V
Short circuit protection: It is defined to be a short circuit load of less than 0.1 ohm

GENERAL SPECIFICATIONS
Hold-up time: >17ms
Efficiency: >80% at full load.
Voltage: 1500VAC from input to output
MTBF: 100,000 hours at full load at 25˚C

ENVIRONMENTAL SPECIFICATIONS
Operating temperature: 0˚C to +50˚C
Storage temperature: -20˚C to +80˚C
Relative humidity: 95% non-condensing

DC Output:
OUTPUT VOLTAGE

OUTPUT CURRENT

REGULATION

OUTPUT

MIN ( A )

MAX ( A )

LOAD

LINE

RIPPLE & NOISE
MAX. [ P-P ]

+5V

0.5

20

±5%

±1%

50mV

+12V1

1

15

±5%

±1%

120mV

+12V2

1

15

±5%

±1%

120mV

+12V3

1

15

±5%

±1%

120mV

-12V

0

0.5

±10%

±1%

120mV

+3.3V

0.5

24

±5%

±1%

50mV

+5VSB

0

2.5

±5%

±1%

50mV

(1) The +3.3V and +5V total output shall not exceed 150watts.
(2) total output for this subject power supply is 500 watts.
(3) Maxmum continuous load combined 12V should not exceed 35A.
(4) Ripply and noise measurements shall be made under all specified load conditions through a single pole low pass filter with 20MHz cutoff frequency. Outputs shall bypassed at the connector with a 0.1uF ceramic disk capacitor and a 10uF electrolytic capacitor to simulate system loading.
(5) -5V is option.

     
   

> Dimension : 240 X 100 X 70mm
> Application : For Industry Use
> Watt : 500
> PFC : Active
> 80 PLUS
> High efficiency
> Low Ripple & Noise
> 100% burn-in under high ambient temperature(50˚C)
> 100% Hi-pot tested
> Complies with EN61000-3-2
> AC input full range


     
   

Product flyer:

Specification:

Drawing:

     
   

24 Pin
Peripheral
FDD
8-Pin
X 1
X 3
X 1
X 1