80 PLUS Verification and Testing Report
AC Input:
> Output over voltage protection
> Short circuit protection on all output
> 100% burn-in under high ambient temperature
> 100% Hi-pot tested
> Line input fuse protection
> With 4cm fan
DC Output:
| Output Voltage |
Min. load |
Max. load |
Load Reg. |
Ripple & Noise |
| +5Vsb |
0.0A |
2.5A |
±5% |
100mV P-P |
| -12V |
0.0A |
0.8A |
±10% |
150mV P-P |
| +12V1 |
0.8A |
17.0A |
±5% |
150mV P-P |
| +12V2 |
0.8A |
17.0A |
±5% |
150mV P-P |
| +5V |
0.5A |
17.0A |
±5% |
100mV P-P |
| +3.3V |
0.5A |
17.0A |
±5% |
100mV P-P |
Note:
• The combined power of +12V1 and +12V2 is 275W max.It is 23A max.
• +3.3V &+5V total output not exceed 95W
• The continuous total output power is 300W max.
> Dimension : 150 mm x81.5 mm x40.6 mm
> Application : For IPC
> ATX 12V / EPS 12V
> Watt : 300
> PFC : Active
> Voltage : 90 to 264 VAC
> Frequency : 47Hz to 63Hz
> Input Current : 115Vac / 3.5A max..
> Inrush Current : No damage shall occur to the
power supply and the fuse shall not open or exceed its maximum rating: NO damage at 25˚C cold start.
> Remote ON/OFF Control : TTL High/PS-OFF; TTL Low/PS-ON
VIL=0.8Vmax, IIL=-1.6mAmax @Vin=0.4V
VIH=2.0Vmin @Iin=-200uA, VIH=5.25Vmax @open ckt
> Operating Temperature : 0˚C to +40˚C
> Storage Temperature : -20˚C to +70˚C
> OPERATING HUMIDITY 10% to 90%,non-condensing
>STORAGE HUMIDITY 5% to 95%, non-condensing
> Hold-up Time : 16 msec (minimum) at 70% of full load at 230Vac input.
> Power Efficiency :80% (min.) at 20%,50%,100% loading line input
> MTBF: 100kHrs Minimum.