80 PLUS Verification and Testing Report
AC Input:
> Input Voltage: 100-240V.
> Efficiency: 80% (min.) at full load(typical) and 115Vac input.
> Input Current : 100Vac / 15A max.
> Inrush Current : 65A max. when AC input 115Vac at 250C cold start.
> Input Frequency : 47Hz~63 Hz.
> Leakage Current: 3.5mA max.
DC Output:
| Output |
Voltage |
Regulation |
Min .Load |
Max .Load |
Ripple |
| V1 |
+5V |
+3,-3% |
0.5A |
30.0A |
50mV |
| V2 |
+3.3V |
+3,-3% |
0.5A |
30.0A |
50mV |
| V3 |
+12V1 |
+3,-3% |
1.0A |
20.0A |
120mV |
| V4 |
+12V2 |
+3,-3% |
1.0A |
20.0A |
120mV |
| V5 |
+12V3 |
+3,-3% |
1.0A |
36.0A |
120mV |
| V6 |
+12V4 |
+3,-3% |
1.0A |
36.0A |
120mV |
| V7 |
-12V |
+10,-10% |
0.0A |
0.8A |
120mV |
| V8 |
+5Vsb |
+3,-5% |
0.0A |
3.5A |
50mV |
Note:
• The continuous total output power is 1200W max.
• The combined power of +5V and +12V2 and +12V3 is 600W max.
• The combined power of +3.3V and +12V1 and +12V4 is 600W max.