80 PLUS Verification and Testing Report
AC Input:
> Input Voltage : 100V - 240V.
> Active PFC :Power Factor : >0.9
> Efficiency : 80%(min.) at full load(typical)
> Input Current : 115Vac / 12.0A ; 230Vac / 6.0A max.
> Inrush Current : 110A max. When AC input 230Vac at 250C cold start.
> Input Frequency : 47Hz~63 Hz.
> Leakage Current : 3.5mA max.
DC Output:
| Output |
Voltage |
Regulation |
Min .Load |
Max .Load |
Ripple |
| V1 |
+5V |
+3,-3% |
2.0A |
30.0A |
50mV |
| V2 |
+3.3V |
+3,-3% |
0.5A |
30.0A |
50mV |
| V3 |
+12V1 |
+3,-3% |
1.0A |
18.0A |
240mV |
| V4 |
+12V2 |
+3,-4% |
1.0A |
18.0A |
240mV |
| V5 |
+12V3 |
+5,-3% |
1.0A |
30.0A |
240mV |
| V6 |
+12V4 |
+3,-3% |
1.0A |
30.0A |
240mV |
| V7 |
-12V |
+9,-5% |
0.0A |
0.8A |
120mV |
| V8 |
+5Vsb |
+5,-3% |
0.0A |
3.0A |
50mV |
Note:
• The continuous total output power is 850W max.
• The combined power of +5V and +3.3V is 180W max.
• Total combined +12V output load not exceed 62A