• Input Voltage: 115V/230V
• Efficiency: >68% @ full load ,nominal line
• Input Current: 115V/4A;230V/2A max.
• Inrush Current: 115Vac/30A (max.),230Vac/60A at 25 ℃ cold start
• Input Frequency: 50/60 Hz
• Leakage Current: 3.5mA max.
| Output |
Voltage |
Regulation |
Min .Load |
Max .Load |
Ripple |
| V1 |
+5V |
±5% |
0.3A |
12.0A |
50mV |
| V2 |
+12V |
±5% |
1A |
13.0A |
120mV |
| V3 |
+3.3V |
±5% |
0.5A |
17.0A
|
50mV |
| V4 |
-12V |
±10% |
0.0A |
0.3A |
100mV |
| V5 |
+5VSB |
±5% |
0.0A |
2.0A |
50mV |
• DIMENSION: W x L x H =82 x 150 x 43.2mm
• 180W 5 Output, AC Input design
• Operating temperature range from 0℃ to 50℃
• Build in DC remote ON/OFF , PG/PF TTL signal
• Build in ball bearing fan
• Compiles with FCC Class B,CISPR Pub. 22,
EN55022 Class B, and CE requirements
• UL/cUL 60950, TUV and CB EN 60950 certified
• MTBF: 100KHRs @ 25℃ per MIL- HDBK-217F
|
|
|
|
|
20 Pin |
P4 MB |
Peripheral |
FDD |
SATA |
X 1 |
X 1 |
X 3 |
X 1 |
Option |
|