dynapowerusa Design to Protect Technology
Products Search
    
 
 
 
Left_CSS









 
2U 460W Power Supply
 
 
VOLTAGE:90~132 or 185~260V, (115/230 auto)
FREQUENCY:50/60Hz
INPUT CURRENT:8A/4A For 115/230VAC
INRUSH CURRENT:60A/80A MAX FOR 115/230

OUTPUT VOLTAGE OUTPUT CURRENT REGULATION OUTPUT
MIN ( A ) MAX ( A ) LOAD

LINE

RIPPLE & NOISE
MAX. [ P-P ]
+5V 3 40 ±5% ±1% 50mV
+12V 2 24 ±5% ±1% 120mV
-5V 0.1 0.3 ±10% ±1% 150mV
-12V 0.1 0.8 ±10% ±1% 150mV
+3.3V 1 20 ±5% ±1% 50mV
+5VSB 0.1 2 ±5% ±1% 50mV

The combined output power +5V&+3.3V shall not exceed 205W.
The total power shall not exceed 460W.
• TEMPERATURE RANGE:Operation 0℃~50℃
• HOLD UP TIME:16ms at maximum load & normal input voltage
• EFFICIENCY:67% TYPICAL(Normal Line)
• ATX 12V / EPS 12V
• POWER GOOD SIGNAL:Should be asserted high to indicate that+5VDC and +3.3VDC
output are above the low voltage thresholds. Compatible signal out with 100ms to 500ms.
• OVER POWER PROTECTION:The power supply shall shout down output power
exceeds 130% to 160%
• OVER VOLTAGE PROTECTION:Standard on +5.0V, set at 6.25VDC ± 0.75VDC
• SHORT CIRCUIT PROTECTION:A short circuit placed between the DC return and
the output shall cause no damage and the power supply shall shutdown.
• EMI:FCC part 15, subpart B, Class B, EN55022 CISPR22 Class B.
• GAENCY APPROVALS:UL60950, CAN/CSA22.2 No.60950, TUV(IEC60950)
• MTBF OF POWER SUPPLY ELECTRONNIS: 100,000 hours. Life expctancy of fan 40,000 hours
• COLLING:By forced air 2x60mm Fan
• DIMENSION:D200 X W100 X H70mm
       Site Map   |   Terms of Use   |   New Account   |   RMA