AC Input:
VOLTAGE: 90~264V, (Active PFC / Full Range)
FREQUENCY: 47~63Hz
Acitve Power factor: >0.9
INPUT CURRENT: 14A for 115Vac max.,7A for 230 Vac max.
INRUSH CURRENT: 75A/150A MAX FOR 115/230
DC Output:
OUTPUT
VOLTAGE |
OUTPUT CURRENT
|
REGULATION |
OUTPUT |
MIN(A) |
MAX(A) |
LOAD |
LINE |
RIPPLE & NOISE
MAX.[P-P] |
+5V
|
0.2 |
35 |
±5% |
±1% |
60mV |
+12V1
|
2
|
16 |
±5% |
±1% |
120mV |
+12V2 |
0 |
16 |
±5% |
±1% |
120mV |
+12V3 |
0 |
16 |
±5% |
±1% |
120mV |
+12V4 |
0 |
16 |
±5% |
±1% |
120mV |
-5V
|
0 |
0.8 |
±10% |
±1% |
120mV |
-12V
|
0 |
1 |
±10% |
±1% |
120mV |
+3.3V
|
0.5 |
30 |
±5% |
±1% |
60mV |
+5VSB
|
0 |
3 |
±5% |
±1% |
60mV |
The combined output power +5V&+3.3V max. Current:48A;+12V1~V4 max,Current:72A
The combined output power +5V&+12V&+3.3V maximum output 980W
The total power shall not exceed 1000W.
> Dimension: D220 X W150 X H86mm
> Cooling: By forced air 2x80mm Fan
> Temperature range: Operation 0˚C~50˚C
> Hold up time: 16ms at maximum load & normal input voltage
> Efficiency: 76% Typical(Normal Line)
> ATX 12V / EPS 12V
> Power good signal: Should be asserted high to indicate that+5VDC and 3.3VDC output
are above the low voltage thresholds. Compatible signal out with 100ms to 500ms.
> Over power protection: The
power supply shall shout down output power exceeds 130% to 160%
> Over voltage protection: Standard on +5V, set at 6.25VDC±0.75VDC
> Short circuit protection: A short circuit placed between the DC return and the output shall
cause no damage and the
power supply shall shutdown.
> EMI: FCC part 15, subpart B, Class B, EN55022 CISPR22 Class B.
> Meet EN-61000-3-2 CLASS D (Active PFC)
> Agency approvals: UL60950, CAN/CSA22.2 No.60950, TUV(IEC60950)
> Remote On/Off control: when ps-on is pulled to TTL low,The DC output is to be Enabled,
When ps-on is pulled to TTL high, The DC output is to disable