VOLTAGE:100~240V(Active PFC/Full Range)
FREQUENCY:47~63Hz
POWER FACTOR CORRECTION:0.95
INPUT CURRENT:8A/4A For 115/230VAC
INRUSH CURRENT:60A/80A MAX FOR 115/230

OUTPUT VOLTAGE OUTPUT CURRENT REGULATION OUTPUT
MIN ( A ) MAX ( A ) LOAD

LINE

RIPPLE & NOISE
MAX. [ P-P ]
+5V 3 40 ±5% ±1% 50mV
+12V 2 28 ±5% ±1% 120mV
-5V 0.1 0.5 ±10% ±1% 150mV
-12V 0.1 0.8 ±10% ±1% 150mV
+3.3V 1 20 ±5% ±1% 50mV
+5VSB 0.1 2 ±5% ±1% 50mV

The combined output power +5V&+3.3V shall not exceed 40A.
The total power shall not exceed 400W.
• TEMPERATURE RANGE:Operation 0℃~50℃
• HOLD UP TIME:16ms at maximum load & normal input voltage
• EFFICIENCY:70% TYPICAL(Normal Line)
• ATX 12V / EPS 12V
• POWER GOOD SIGNAL:Should be asserted high to indicate that+5VDC and +3.3VDC output are above the low voltage thresholds. Compatible signal out with 100ms to 500ms.
• OVER POWER PROTECTION:The power supply shall shout down output power exceeds 130% to 160%
• OVER VOLTAGE PROTECTION:+5V, +3.3V and +12V DC outputs set at 110%-130%
• SHORT CIRCUIT PROTECTION:A short circuit placed between the DC return and the output shall cause no damage and the power supply shall shutdown.
• EMI:FCC part 15, subpart B, Class B, EN55022 CISPR22 Class B.
• Meet EN-61000-3-2 CLASS D ( Active PFC )
• GAENCY APPROVALS:UL60950, CAN/CSA22.2 No.60950, TUV(IEC60950)
• MTBF OF POWER SUPPLY ELECTRONNIS: 100,000 hours. Life expctancy of fan 40,000 hours
• COLLING:By forced air 1x40mm Fan (Each module)
• DIMENSION:D280 X W101 X H84mm