> AC Input:
- VOLTAGE: 90~264VAC Full Range
- FREQUENCY: 50/60Hz.
- INPUT CURRENT: 10A for 115V AC, 5A for 230VAC.
- INRUSH CURRENT: 60A for 115VAC, 80A for 230VAC
Each of the 1+1 redundant power supply module shall be capable of supplying the output
currents of as below subject to the listed conditions and a total output power of 550watts.
Due to the active current share, the actual maximum steady state current from each output
shall be about half of the maximum current specified.
| Output Voltage |
+5V DC |
+12V DC |
+3.3V DC |
-12V DC |
+5VSB |
| Output Current(Max) |
32A |
38A |
25A |
1A |
3A |
| Output Current(Min.) |
1A |
3A |
1A |
0A |
0.1A |
| Ripple/Noise Max.(P-P): |
50mv |
70mv |
50mv |
70mv |
50mV |
| Line Regulation: |
±1﹪ |
±1﹪ |
±1﹪ |
±1﹪ |
±1﹪ |
| Load Regulation: |
±5﹪ |
±5﹪ |
±5﹪ |
±5﹪ |
±5﹪ |
REMARKS:
1.Total Max output of +5V AND +3.3V not exceed 200W
2.Power module Total output power not exceed 550W forTC-550RVN2
3.Noise bandwidth is from DC to 20MHz.
> DIMENSION:D300 X W101 X H84mm / D11.81 x W3.98 x H3.3 (inches)
> COOLING: BY BALL BEARING DC FAN
> TEMPERATURE RANGE: Operation 0℃~50℃, Non Operating: -20℃to +70℃
> Output voltage hold up time: Upon loss of an ac input at any input voltage between 115/230V, the output voltages of the system shall remain in regulation for at least 16 ms at full output loads.
> EFFICIENCY: 76% Typical at full load
> ATX 12V / EPS 12V
> Power good signal: The system shall have an active high TTL compatible signal capable of sinking 1mA and sourcing 100uA. The signal shall become active within 100 to 500 ms from the instant +5V output reaches a steady state level within the specified regulation limits. It shall become inactive at least 1 ms before +5V drops to below the lower regulation limit.
> OVER POWER PROTECTION: OVER 110% ~ 150% of rated load Shut down latch off
> OVER VOLTAGE PROTECTION: Standard on +5.0V output, set at 6.9VDC ±0.75VDC
> SHORT CIRCUIT PROTECTION: All output equipped with short circuit.(Shut down o/p voltage, re-power on to recover).
> EMI/RFI standards: FCC part 15, class A, EN55022 CISPR22 Class A
> AGENCY APPROVALS: UL/cUL60950-1, TUV EN60950-1, CB Certification, CCC
> Mean Time Between Failure(MTBF): Using MIL - HDBK -217F the calculated MTBF 100,000 hours.
|