> AC Input:
- VOLTAGE: 100~240V(Active PFC/Full Range)
- FREQUENCY: 47~63Hz
- POWER FACTOR CORRECTION: 0.95
- INPUT CURRENT: 10A/7A For 115/230VAC
- INRUSH CURRENT: 60A/80A MAX FOR 115/230
OUTPUT
VOLTAGE |
OUTPUT CURRENT |
REGULATION |
OUTPUT |
| MIN(A) |
MAX(A) |
LOAD |
LINE |
RIPPLE & NOISE
MAX.[P-P] |
+5V |
3 |
50 |
±5% |
±1% |
50mV |
+12V |
2 |
40 |
±5% |
±1% |
120mV |
-5V |
0.1 |
0.3 |
±10% |
±1% |
150mV |
-12V |
0.1 |
0.8 |
±10% |
±1% |
150mV |
+3.3V |
1 |
30 |
±5% |
±1% |
50mV |
+5VSB |
0.1 |
2 |
±5% |
±1% |
50mV |
The combined output power +5V&+3.3V shall not exceed 50A.
The total power shall not exceed 600W.
> DIMENSION: D280 X W150 X H86mm
> COOLING: By forced air 1x40mm Fan (Each module)
> TEMPERATURE RANGE: Operation 0˚C~50˚C
> HOLD UP TIME: 16ms at maximum load & normal input voltage
> EFFICIENCY: 70% TYPICAL(Normal Line)
> ATX 12V / EPS 12V
> POWER GOOD SIGNAL: Should be asserted high to indicate that+5VDC and +3.3VDC
output are above the low voltage thresholds. Compatible signal out with 100ms to 500ms.
> OVER POWER PROTECTION: The power supply shall shout down output power exceeds 130% to 160%
> OVER VOLTAGE PROTECTION: +5V, +3.3V and +12V DC outputs set at 110%-130%
> SHORT CIRCUIT PROTECTION: A short circuit placed between the DC return and
the output shall cause no damage and the power supply shall shutdown.
> EMI: FCC part 15, subpart B, Class B, EN55022 CISPR22 Class B.
> Meet EN-61000-3-2 CLASS D ( Active PFC )
> AGENCY APPROVALS: UL60950, CAN/CSA22.2 No.60950, TUV(IEC60950)
> MTBF OF POWER SUPPLY ELECTRONNIS: 100,000 hours. Life expctancy of fan 40,000 hours |