dynapowerusa Design to Protect Technology
Products Search
    
 
 
 
Left_CSS









 
You are here: Home > Product > Sure Star > N+1 Redundant
1U 600W Power Supply
 
 
> AC Input:
- VOLTAGE: 100~240V(Active PFC/Full Range)
- FREQUENCY: 47~63Hz
- POWER FACTOR CORRECTION: 0.95
- INPUT CURRENT: 10A/7A For 115/230VAC
- INRUSH CURRENT: 60A/80A MAX FOR 115/230
OUTPUT
VOLTAGE
OUTPUT CURRENT REGULATION OUTPUT
MIN(A) MAX(A) LOAD LINE RIPPLE & NOISE
MAX.[P-P]
+5V
3 50 ±5% ±1% 50mV
+12V
2
40 ±5% ±1% 120mV
-5V
0.1 0.3 ±10% ±1% 150mV
-12V
0.1 0.8 ±10% ±1% 150mV
+3.3V
1 30 ±5% ±1% 50mV
+5VSB
0.1 2 ±5% ±1% 50mV

The combined output power +5V&+3.3V shall not exceed 50A.
The total power shall not exceed 600W.
> DIMENSION: D280 X W150 X H86mm
> COOLING: By forced air 1x40mm Fan (Each module)
> TEMPERATURE RANGE: Operation 0˚C~50˚C
> HOLD UP TIME: 16ms at maximum load & normal input voltage
> EFFICIENCY: 70% TYPICAL(Normal Line)
> ATX 12V / EPS 12V
> POWER GOOD SIGNAL: Should be asserted high to indicate that+5VDC and +3.3VDC
   output are above the low voltage thresholds. Compatible signal out with 100ms to 500ms.
> OVER POWER PROTECTION: The power supply shall shout down output power exceeds 130% to 160%
> OVER VOLTAGE PROTECTION: +5V, +3.3V and +12V DC outputs set at 110%-130%
> SHORT CIRCUIT PROTECTION: A short circuit placed between the DC return and
   the output shall cause no damage and the power supply shall shutdown.
> EMI: FCC part 15, subpart B, Class B, EN55022 CISPR22 Class B.
> Meet EN-61000-3-2 CLASS D ( Active PFC )
> AGENCY APPROVALS: UL60950, CAN/CSA22.2 No.60950, TUV(IEC60950)
> MTBF OF POWER SUPPLY ELECTRONNIS: 100,000 hours. Life expctancy of fan 40,000 hours
24 Pin
P4 MB
Peripheral
FDD
SATA
8-Pin
X 1
X 1
X 11
X 3
X 2
X 1
       Site Map   |   Terms of Use   |   New Account   |   RMA