1.1 AC Input Voltage: 100 to 132 or 198 to 264 User selectable 50 to 60 Hz.
1.2 DC Output: 350W maximum
| |
Output-1 |
Output-2 |
Output-3 |
Output-4 |
Output-5 |
| Voltage: |
+5V DC |
+12V DC |
-5V DC |
-12V DC |
+3.3V DC |
| Maximum Load: |
40A |
12A |
0.5A |
0.8A |
20A |
| Minimum Load: |
6A |
3A |
0.1A |
0.1A |
0.3A |
*** Note: Output-1 + Output-5 total 200W maximum |
| Ripple: |
50mv |
120mv |
50mv |
120mv |
40mv |
| Ripple/Noise: |
100mv |
150mv |
100mv |
240mv |
40mv |
| Line Regulation: |
±1% |
±1% |
±1% |
±1% |
±1% |
| Output Regulation: |
±5% |
±6% |
±10% |
±10% |
±5% |
| Cross Regulation: |
±5% |
±6% |
±10% |
±10% |
±5% |
Note:
1.Noise Test - Noise bandwidth is from DC to 20 MHz.
2.Ripple frequencies greater than 1MHz shall be attenuated by the measurement System.
3.Add 0.1uF/10uF capacitor at output connector terminals for ripple and noise measurements.
4.The combined total power from +5V and +3.3V shall not exceed 200W.
5.+5V SB DC Output 1.5A. (Peak 2A)