Features

  • E.O.L. (End of Life) as of 1/30/19
  • Replaced by SS-1U40ES
  • 400W
  • Dimensions(mm): 220 x 100 x 40.5
  • Application: For Server & Workstation
  • ATX 12V / EPS 12V
  • PFC : Active
  • 80 PLUS
  • High efficiency

1U Power Supply 80Plus 400W TC-1U40P80 Product Description

The 1U Power Supply 80Plus 400W TC-1U40P80 is the perfect upgrade or replacement for powering an AMD or Intel based server. Ideal for 2U or 3U server cases, this 2U power supply provides your system with a 80 Plus certified power solution, as well as protection against over load, over voltage and over current situations – the perfect solution for delivering stable power to the most demanding devices. The 400W power supply also comes with a built-in, ball-bearing fan that helps provide superior air flow, ensuring optimum operating temperatures for long-lasting performance.

INPUT SPECIFICATIONS
Input voltage: 90 to 264 VAC
Input frequency: 115V: 60Hz; 230V: 50Hz
Inrush current: 60Amps-peak/115Vac; 90Amps-peak/230Vac
Input current: 5Amps/115Vac; 3Amps/230Vac

OUTPUT SPECIFICATIONS
Over voltage protection:+5V output: 5.85V min, 6.82V max..; +3.3V output: 3.5V min., 4.5V max;
Overload protection: +5V: 50Amps ; +3.3V: 50Amps; +12V: 22Amps;
Short circuit protection: The short circuit on any DC output shall not cause any damage to the power supply, including the primary fuse.

 

GENERAL SPECIFICATIONS
Hold-up time: 17ms at 115Vac/60Hz, 17ms at 230Vac/50Hz.
Efficiency: 80% min. 115/230Vac at full load
MTBF: 100,000 hours
Power good signal: 100ms to 500 ms

ENVIRONMENTAL SPECIFICATIONS
Operating temperature: 0˚C to +40˚C
Storage temperature: -20˚C to +80˚C
Relative humidity: 5% to 95% RH non-condensing

DC OUTPUTS

OUTPUT VOLTAGE OUTPUT CURRENT REGULATION OUTPUT
MIN ( A ) MIN ( A ) LOAD LINE RIPPLE & NOISE
MAX. [P-P]
+5V 0.5 20 ±5% ±1% 50mV
+12V1 1.5 16 ±5% ±1% 120mV
+12V2 1.5 16 ±5% ±1% 120mV
-12V 0 0.5 ±10% ±1% 120mV
+3.3V 0.5 20 ±5% ±1% 50mV
+5VSB 0 2.5 ±5% ±1% 50mV

 

(1) The +3.3V and +5V total output shall not exceed 150watts.
(2) total output for this subject power supply is 400 watts.
(3) Ripply and noise measurements shall be made under all specified load conditions through a single pole low pass filter with 20MHz cutoff frequency. Outputs shall bypassed at the connector with a 0.1uF ceramic disk capacitor and a 10uF electrolytic capacitor to simulate system loading.
(4) -5V is option.

Connectors:

24-pin
peripheral
FDD
8-Pin
24 Pin Peripheral FDD 8-Pin
X 1 X 3 X 1 X 1